@Processing
frequency
Total frequency
In the process frequency display, the total frequency
of
all cycles
and the processing frequency
of
each cycle are displayed.
•
Each time when the "TIME" button is pressed, the processing
frequency of each
cycle are displayed.
R
··ALL" stands for the total frequency, and
"cSl"
for LlQUD STERI,
"cS2"
for STERI KEEP WARM, "cS3" for MERT/KEEP WARM
and
"cS4" for INSTRUMENT STERI, respectively. C cle-wise
Processing
frequency
·When
the "START" button is pressed while pressing the
·SET/CINFIRM" buttons, the total processing frequency and
operation frequency
of
each cycle are cleared.
C S ,
"--r--I~Cycl~e---.J1
1"""''--'' ...... _..0.....,=1
L-
___
--=''-'''O.....,H
~~c:~~
I
@Hlstory
of
errors
Error No., error code and error occurring process No. are displayed.
The latest error data is displayed in the first place.
•
The error No. is changed by pressing
the"
...
·or
....
" button and
the history
of
errors can be checked.
The error No. can be recorded for 8 in number
at
the maximum.
If more than 9 errors occur, the oldest error is deleted and new
error is recorded instead.
E
6
t
·When
the "START" button is pressed while pressing the
·SET/CONFIRM" button, the error data is deleted.
(Total
errors are not deleted.)
I Error code I
.Error
Codes.
2
+-t
Error
No. I
04--
Error
occurring
process
No.
1 :
Lateral
thermistor
(TH1)
Open
2 :
Bottom
thermistor
(TH3)
Open
6 :
Movable
handle
Unlock
impossible
7 :
Movable
handle
and
lid
Lock
impossible
3:
Lateral
thermistor
Abnormal
temperature
8:
Abnormally
high
pressure
4 : Object temperature sensor
(TH2)
Abnormal
temperat
9:
Low
pressure
5:
Bottom
thermistor
Abnormal
temperatura
10:
EEPROM
communication
error
<
Error
occurring
process Nos.>
Process
No
Error
Occurring
Process
Description
Process
No
0
Stand-by
6
1
Reservation
7
2
Heating 1
Up
to
90"C
8
3
Heating 2
From
90<>C
to
boiling
poin1
9
4
Exhaust
10
5
Heating 3
THl
temp. rises
up
to
11
the
preset temp.
@Boiling
Poing
setting
Change the boiling point temperature according to the altitude
of
the place for installation by pressing
the"
...
·or
.....
button.
·When the 'START" button is pressed while pressing the
·SET/CONFIRM" button, the content
of
the change is written in
the
non-volatile memory.
(The
boiling temperature has been set at 100"C in the factory.)
Error
Occurring
Process
Description
Heating 4
TH2 temp. rises
up
to
the preset temp.
SterilizationlMelting
Cooling 1
Down
to
boiling
point
Cooling 2
Before
cooling point
Keep warm
Completion
bP
,
~OH
Set
temperature
I
• When setting the boiling point, refer to the table (P
__
)
of
the altitude and atmospheric pressure in the
standard atmosphere and the
boiling point of water.
-
25-