Labo Autoclave
Thank you for purchasing a Sanyo Autoclave.
Please read this instruction manual carefully
before using the product.
After reading this manual, store it in a readily
accessible place along with the warranty card.
Please pay particular attention to the
S Safety Precautions T section on page 1 to 6.
Contents
Page
How to Use
On Power Failure . . . . . . . . . . . . . . . . . . . . 24
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 26
Troubleshooting . . . . . . . . . . . . . . . . 27 ~ 28
Specifications . . . . . . . . . . . . . . . . . . . . . . 29
Basic operating procedure . . . . . . 14 ~ 22
For continuous use . . . . . . . . . . . . . . . 22
To stop the operation
. . . . . . . . . . . . . . 23
For timer operation
. . . . . . . . . . . . . . . . 23
High-pressure Steam Sterilizer
INSTRUCTION MANUAL
Model No. indication
Safety Precautions . . . . . . . . . . . . . . . 1 ~ 6
Precautions in Use . . . . . . . . . . . . . . . . . . . 7
Before Using the Product . . . . . . . . . . . . . . 8
Sterilization Objects . . . . . . . . . . . . . 12 ~ 13
Names and Functions of Part . . . . . . . 9 ~ 10
Explanation of Label . . . . . . . . . . . . . . . . . 11
MLS
-
3751
MLS
-
3781
Model
Nos.
On Voice Guide . . . . . . . . . . . . . . . . . . . . . 25

Questions and Answers

  • M
    Meghan BatesAug 15, 2025
    Why won't the temperature rise during heating in my Sanyo Laboratory Equipment?
    • K
      Kenneth ByrdAug 16, 2025
      If the temperature in the heating process of your Sanyo Laboratory Equipment is not rising and failing to reach the sterilization temperature, check if the exhaust hose is bent and straighten it. Also, verify that the correct cycle is selected instead of the melting cycle. If the boiling point isn't properly set for your altitude, it is best to contact your dealer.
  • N
    Nathan RoseAug 19, 2025
    What to do if steam leaks from the safety valve of my Sanyo Laboratory Equipment?
    • N
      nguyenangelaAug 19, 2025
      If steam is leaking from the safety valve vent of your Sanyo Laboratory Equipment, indicating abnormally high pressure during sterilization, first stop the operation. Make sure that sterilization objects are not blocking the temperature sensor inside the chamber. If you are sterilizing a small amount of liquid in a large container with a narrow mouth, fill the container halfway or transfer the liquid to a container with a wider mouth. Additionally, ensure that beakers or similar items are not being sterilized with their openings facing upward; instead, direct the openings downward or lay them down.
  • C
    Cassandra PetersAug 21, 2025
    What to do if the cover of my Sanyo Laboratory Equipment won't open?
    • M
      michele86Aug 21, 2025
      If the cover of your Sanyo Laboratory Equipment will not open, ensure the power switch is turned ON and wait for the power to be restored if there was an outage. If the COVER LOCK lamp is lit, the temperature and pressure inside the chamber are still too high; wait until the COVER LOCK lamp goes out.
  • M
    monica61Aug 25, 2025
    Why won't my Sanyo Laboratory Equipment start?
    • J
      jamiechristensenAug 25, 2025
      If the operation of your Sanyo Laboratory Equipment will not start, first ensure that the power switch is turned ON. Then, firmly press down the handle to close the cover until you hear a buzzer sound. If a timer operation is in progress, press the stop button to cancel it.
  • M
    Michael SheppardAug 27, 2025
    How to fix power not supplied to Sanyo Laboratory Equipment?
    • S
      Sarah HatfieldAug 27, 2025
      If power is not being supplied to your Sanyo Laboratory Equipment, ensure that the power supply is turned ON. If there has been a power outage, wait until the power is restored.
  • M
    Mary MillerAug 30, 2025
    What causes the 'pressure rises abnormally high' error on my Sanyo Laboratory Equipment?
    • K
      Kenneth RobertsonAug 30, 2025
      If your Sanyo Laboratory Equipment displays an error sign indicating abnormally high pressure, check if the exhaust hose is bent. If it is, take out the exhaust tank and straighten the hose. Note that the cautionary message may appear several times after straightening the hose; if the issue persists, press the stop button and try again. Also, make sure that the mouth of the sterilization bag is open and that the bag contains 300 ml of water. If the boiling point is not set suitably to the altitude, ask your dealer to adjust it.
  • C
    Casey LopezSep 2, 2025
    How do I fix the 'exhaust hose is bent' message on my Sanyo Laboratory Equipment?
    • T
      Thomas HernandezSep 2, 2025
      If you receive a cautionary message indicating that the exhaust hose is bent on your Sanyo Laboratory Equipment, remove the exhaust tank and straighten the exhaust hose. After straightening, the message may appear several times. If the issue persists, press the stop button and try again. If the product does not return to normal, contact the dealer from whom you purchased the product.
  • M
    Michelle ShermanSep 6, 2025
    What to do if the cover of my Sanyo Laboratory Equipment doesn't close?
    • K
      Kimberly JonesSep 6, 2025
      If the cover of your Sanyo Laboratory Equipment will not close, wait until the temperature inside the chamber lowers below 60°C.
  • M
    Melissa WoodSep 8, 2025
    What does it mean when my Sanyo Laboratory Equipment says 'Cover is not closed completely'?
    • D
      Denise BellSep 9, 2025
      If you receive a cautionary message that the cover of your Sanyo Laboratory Equipment is not closed completely, press down the handle forcefully until you hear a buzzer sound.
  • M
    Melissa BeardSep 12, 2025
    What to do if the 'heating water is scarce' error appears on my Sanyo Laboratory Equipment?
    • K
      Keith GomezSep 12, 2025
      If your Sanyo Laboratory Equipment displays an error indicating that the heating water is scarce or depleted, supply heating water in the chamber.

Summary

Safety Precautions

Safety Warning Classifications

Defines DANGER, WARNING, and CAUTION levels for safety precautions.

Safety Symbols

Explains the meaning of safety symbols used in the manual.

Product Warning Labels

Explains the meaning of warning labels affixed to the product.

Precautions in Use

Before Using the Product

Installation

Instructions and requirements for installing the product.

Power Supply and Ground Connections

Details on connecting the product's power supply and grounding.

Names and Functions of Parts

Component Identification

Identifies and describes the various parts and components of the product.

Explanation of Labels

Product Label Explanations

Explains the purpose and content of rating and warning labels on the product.

Sterilization Objects

Sterilizing Liquids and Culture Medium

Guidelines for sterilizing and melting liquids, including culture mediums.

Sterilizing Equipment

Instructions for sterilizing equipment such as glassware.

Sterilizing Waste and Liquids in Bags

Procedures for sterilizing waste, liquids in bags, and large containers.

How to Use

Basic Operating Procedure

Detailed steps for performing standard sterilization cycles.

To Stop Operation

For Timer Operation

On Voice Guide

Voice Guide Modes

Explains Standard and Warning modes for voice guidance.

Changing Voice Guide Settings

Steps to adjust voice guide settings such as mode and volume.

Maintenance

Cleaning and Care Procedures

Instructions for cleaning the product, exhaust tank, chamber, and cover packings.

Troubleshooting

Troubleshooting Common Issues

Checks and remedies for common operational problems before contacting service.

Normal Operating Symptoms

Explains normal operational sounds and heating that may be mistaken for problems.

Error Messages and Cautionary Signs

How to interpret and resolve cautionary messages and error codes.

Specifications

Sanyo MLS-3751 Specifications

General IconGeneral
BrandSanyo
ModelMLS-3751
CategoryLaboratory Equipment
LanguageEnglish