3
2-2. Major Component Specifications
Model SA–128S5
Controller PCB
Part No.
Controls
Control circuit fuse
Remote Control Unit
Compressor
Type Rotary (Hermetic)
Compressor model C-R110H5H 80619445
Source 220–240V Single phase 50Hz
Nominal output W 1,100
Compressor oil ... Amount cc SUNISO 4GSD-T ... 550
Coil resistance (Ambient temp. 25°C) C–R : 1.962
C–S : 5.38
Safety devices Type
External protector
Overload relay
MRA98619-9200
Operating temp. Open °C
150±5
Close °C
69±11
Operating amp.(Ambient temp. 25°C)
Trip in 6 to 16 sec. at 22.5A
Run capacitor µF 25.0
VAC 400
Fan & Fan Motor Indoor Outdoor
Type Centrifugal Propeller
Dia. / Depth mm ø210 / D96 ø320 / D —
Fan motor model ... Q'ty YSK70-4A-661 ... 1
Source 220–240V Single phase 50Hz
No. of poles ... rpm (230 V, High) 4 ... 1,010
Nominal output W 20
Coil resistance (Ambient temp. 20°C) WHT-BRN : 60.0
WHT-YEL : 19.6
YEL-ORG(PNK) : 62.7
Safety devices Type Internal protector
Operating temp. Open °C 130±5
Close °C Automatic reclosing
Run capacitor µF 3.5
VAC 440
Heat Exch. Coil
Coil Evaporator Condenser
Rows 2 3
Fin pitch mm 1.4 1.6
Face area
m
2
0.095 0.155
External Finish Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.