C. Check "OPERATION selector" switch in the indoor unit.
D. Check transformer in indoor unit.
E. Check fuse on the indoor PCB Ass'y.
F. Check TIMER on the remote control unit.
•
Timer is turned ON. Check to see
if is displayed on remote
control.
YES
Cancel the timer mode.
ON
OK
OK
•
Check fuse on indoor PCB Ass'y
for continuity. (F01)
•
Check operation lamp to see
if light is ON.
Light is OFF
•
Measure resistance of primary and
secondary winding of transformer.
(TR)
Indoor PCB Ass'y or switch Ass'y is
defective.
OK
OK
•
Measure resistance of indoor and/or
fan motor winding.
(FM)
•
Measure resistance of compressor
motor winding. (CM)
OK
•
Measure coil resistance of power
relay. (PR)
Replace the fuse.
If fuse has been blown,
•
Measure resistance of primary and
secondary winding.
(TR)
YES
NO
•
OPERATION selector switch is set
in ON position.
Set OPERATION selector switch
to ON.
Switch Ass'y or indoor PCB Ass'y
is defective.