Indoor Unit SAP-K97GHAX
Outdoor Unit SAP-C97GHAX
32
Rating conditions: Indoor air temperature: 27
C D.B. / 19 C W.B.
Outdoor air temperature: 35
C D.B.
Full Load conditions: Indoor air temperature: 32
C D.B. / 23 C W.B.
Outdoor air temperature: 43
C D.B.
Cooling
Rating conditions: Indoor air temperature: 20 C D.B.
Outdoor air temperature: 7
C D.B. / 6 C W.B.
Full Load conditions: Indoor air temperature: 27
C D.B.
Outdoor air temperature: 24
C D.B. / 18 C W.B.
Heating
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220/230/240V Single phase 50Hz
Rating Conditions Running Amps. A 0.17 0.21 4.02 4.4
Power Input
k
W 0.028 0.048 0.884 0.960
Full Load Conditions Running Amps. A 0.17 0.21 4.89 5.27
Power Input
k
W 0.028 0.048 1.098 1.174
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220/230/240V Single phase 50Hz
Rating Conditions Running Amps. A 0.17 0.21 3.72 4.1
Power Input
k
W 0.028 0.048 0.854 0.930
Full Load Conditions Running Amps. A 0.17 0.21 4.89 5.27
Power Input
k
W 0.028 0.048 1.098 1.174