33
Rating conditions: Indoor air temperature: 27
C D.B. / 19 C W.B.
Outdoor air temperature: 35
C D.B.
Full Load conditions: Indoor air temperature: 32
C D.B. / 23 C W.B.
Outdoor air temperature: 43
C D.B.
Cooling
Rating conditions: Indoor air temperature: 20 C D.B.
Outdoor air temperature: 7
C D.B. / 6 C W.B.
Full Load conditions: Indoor air temperature: 27
C D.B.
Outdoor air temperature: 24
C D.B. / 18 C W.B.
Heating
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220/230/240V Single phase 50Hz
Rating Conditions Running Amps. A 0.19 0.39 5.62 6.2
Power Input
k
W 0.031 0.090 1.184 1.305
Full Load Conditions Running Amps. A 0.19 0.39 7.19 7.77
Power Input
k
W 0.031 0.090 1.555 1.676
Indoor Unit Outdoor Unit Complete Unit
Fan Motor Fan Motor Compressor
Performance at 220/230/240V Single phase 50Hz
Rating Conditions Running Amps. A 0.19 0.39 5.32 5.9
Power Input
k
W 0.031 0.090 1.154 1.275
Full Load Conditions Running Amps. A 0.19 0.39 7.19 7.77
Power Input
k
W 0.031 0.090 1.555 1.676