EasyManua.ls Logo

Sanyo SAP-CMRV3143GJH - Page 44

Sanyo SAP-CMRV3143GJH
45 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Four-room operation
Indoor unit
Indoor Unit Capacity (kW)
Conbination
Room A Room B Room C Room D Total Performance Power Input (W) Current (A)
Min. - Max. Min. - Max.
2.8+2.8 Heating 2.50 2.50 2.50 2.50 10.0 2,170 9.7
2.8+2.8 1.7 - 10.8 820 - 2,350
Cooling 2.25 2.25 2.25 2.25 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+2.8 Heating 2.40 2.40 2.40 2.80 10.0 2,170 9.7
2.8+3.6 1.7 - 10.8 820 - 2,350
Cooling 2.10 2.10 2.10 2.70 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+2.8 Heating 2.25 2.25 2.75 2.75 10.0 2,170 9.7
3.6+3.6 1.7 - 10.8 820 - 2,350
Cooling 2.00 2.00 2.50 2.50 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+2.8 Heating 2.10 2.10 2.10 3.70 10.0 2,170 9.7
2.8+5.0 1.7 - 10.8 820 - 2,350
Cooling 1.90 1.90 1.90 3.30 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+3.6 Heating 2.20 2.60 2.60 2.60 10.0 2,170 9.7
3.6+3.6 1.7 - 10.8 820 - 2,350
Cooling 1.80 2.40 2.40 2.40 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+2.8 Heating 2.00 2.00 2.40 3.60 10.0 2,170 9.7
3.6+5.0 1.7 - 10.8 820 - 2,350
Cooling 1.75 1.75 2.30 3.20 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
3.6+3.6 Heating 2.50 2.50 2.50 2.50 10.0 2,170 9.7
3.6+3.6 1.7 - 10.8 820 - 2,350
Cooling 2.25 2.25 2.25 2.25 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+3.6 Heating 1.95 2.30 2.30 3.45 10.0 2,170 9.7
3.6+5.0 1.7 - 10.8 820 - 2,350
Cooling 1.70 2.15 2.15 3.00 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
2.8+2.8 Heating 2.00 2.00 2.00 4.00 10.0 2,170 9.7
2.8+7.0 1.7 - 10.8 820 - 2,350
Cooling 1.65 1.65 1.65 4.05 9.0 1,940 8.8
1.2 - 10.5 620 - 2,380
Outdoor Unit SAPCMRV3143GJH
2.8: SAP-#MRV93GJH
3.6: SAP-#MRV123GJH
5.0: SAP-#MRV183GJH
7.0: SAP-#MRV243GJH
NOTE
41