Indoor Unit SAP-K127GHAX
11
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Controller PCB
Part No. CR-K127GHAX
Controls Microprocessor
Control circuit fuse 250V 3.15A
Remote Control Unit
RCS-7HS2E-G
Fan
Part No. Cross-Flow
Q'ty … Dia. and Length 1 … D100 / L637
Fan Motor
Type AC Motor
Model … Q'ty IBH-884-066B … 1
No. of Poles 4
Rough Measure RPM (Cool/Heat) 1,300 / 1,230
Nominal output W 12.5
Coil resistance
Ohm
BRN-WHT : 234
(Ambient temp. 20
C) PNK(RED)-WHT : 209
Safety devices Type Thermal fuse
Operating temp. Open
C 130
Close
C-
Run capacitor (on controller PCB)
Micro F
Ohm
1.5
VAC 450
Flap Motor
Type Stepping Motor
Model 24BYJ48-916
Rating DC 12V
Coil Resistance Each Pair of Terminal : 200+/- 7%
(Ambient Temp.25
C)
Heat Exchanger Coil
Coil Aluminum Plate Fin / Copper Tube
Rows 2
Fin pitch mm 1.1
Face area
m
2
0.162

Table of Contents