1-3. Other Component Specifi cations
Outdoor Units SPW-C256VH8
MODEL No.
Outdoor Unit SPW-C256VH8
Power Transformer
Rated
Source VAC, Hz
Secondary
Coil resistance
Ω
Thermal cut off temperature °C
Thermistor (Coil / Air sensor): TH1, TH2, TH3, TH4
PB2M-41E-S1, DTN-C532G3H
Resistance
kΩ
–10°C: 23.7±5% 20°C: 6.5±5%
–5°C: 18.8±5% 30°C: 4.4±5%
0°C: 15.0±5% 40°C: 3.1±5%
5°C: 12.1±5% 45°C: 2.6±5%
10°C: 9.7±5% 50°C: 2.1±5%
Thermistor (Discharge gas sensor): TH5
DTN-C583G3U-TKS236B
Resistance
kΩ
60°C: 13.8±5% 90°C: 5.1±5%
70°C: 9.7±5% 100°C: 3.8±5%
75°C: 8.2±5% 110°C: 2.8±5%
80°C: 7.0±5% 120°C: 2.2±5%
85°C: 5.9±5% 130°C: 1.7±5%
Relay (Comp. Magnetic Contactor)
Coil rated VAC
Contact rating VAC, A
Coil resistance (at 20°C)
Ω
Sol-Control-Valve
Sol-control-valve UKV-18D13
Magnetic coil UKV-U013E, DC12V
4 way valve
4 way valve STF-0202G
Elec magnetic coil STF-01AJ512D1, AC 220-240 V, 50Hz