– 42 –
SM830033
2
2. Processes and functions
Fig. 21
(1) When the unit is stopped, the Auto-flap returns to F5 position.
(2) When the airflow direction is set (an optional setting), the auto and Swing settings will
be released. To return the mode to auto-flap control, change the operation mode.
(3) Once Auto-flap is set, the flap position will be input in the memory.
(4) When the operation mode is changed, the unit starts to search flap position. (if a
search action for sensing flap position is not succeeded in one minute, only the swing
is operated.)
2-18 Drain Pump Control
1) When the compressor is ON in cooling operation, the drain pump will start to operate.
2) When the compressor is stopped by freeze prevention function, the drain pump will
run for 20 minutes.
3) After the float switch turns ON, the drain pump will start to operate 5 minues. After the
recovery of the float switch, the drain pump turns OFF.
2-17 Auto-flap Control
Auto flap can control the air flow in 5 steps.
Auto-flap
20°
40°
F1
F2
F3
F4
F5
0450_M_S
Operation mode
Flap position
Automatic setting Optional setting
Cooling/dehumidifying F2 F1 • F2 • F3 • Swing
Fan F2 F1 • F2 • F3 • F4 • F5 • Swing
Heating F4 F1 • F2 • F3 • F4 • F5 • Swing
Standby for heating
F2 (The flap returns to the original position after
release of the standby mode.)