EasyManua.ls Logo

Sanyo VCC-HD4600P - Basic Connections

Sanyo VCC-HD4600P
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
Basic Connections
24 VAC
12 VDC
Monitor
High-definition monitor
PC
Target
󱤩󱤪
󱤫
󱤨
󱤬
12 VDC
-
+
24 VAC
GND
~
~
󱤨 Power Connection
Attach the supplied power connecter into the power terminal.
Loosen the screws on the side face of the connecter, connect
the power cables to it, and tighten the screws.
Connection method depends on the power supply (24 VAC or
12 VDC).
Connection to 24 VAC power supply:
Although the power terminals have no polarity, the earth grounding wire must be
connected to the COM (GND) terminal.
Connection to 12 VDC power supply:
Note the polarity (+/–) of the power terminals when connecting the camera to a 12
VDC power supply.
Incorrect polarity may cause damage to the camera.
To prevent a fire hazard use any UL listed wire rated VW-1. Be sure to
use an 18AWG or thicker wire power cable.
If you must use a long power cable, determine the cable type by
ensuring that the voltage at the 24 VAC/12 VDC terminal is within the
operating range of the camera.
When the camera is powered on, the POWER indicator lights up and the live video
is displayed on the connected monitor.
L5DH2VCC-HD4600PSMGB.inddSec1:6L5DH2VCC-HD4600PSMGB.inddSec1:6 2009/10/2018:42:172009/10/2018:42:17