Do you have a question about the Sartorius CP153 and is the answer not in the manual?
Operator responsibility for modifications, connections, and minimum operating specifications.
Step-by-step guide for assembling the analytical draft shield chamber components.
Instructions for fitting and securing the 3-sided draft shield onto the balance.
Specific steps for connecting the AC adapter to CP225D and other balance models with different weighing capacities.
Specific instructions for leveling balances with a weighing capacity up to 10 kg using the front feet.
Detailed description of the balance/scale's display indicators and physical operating keys/buttons.
Steps for preparing the balance/scale, including turning it on and taring.
Important note regarding the use of the under-balance weighing port with legal measuring instruments.
Requirements for internal calibration of verified instruments after warmup before legal use.
Describes the sequence for calibration/adjustment and available factory settings for modes.
Step-by-step guide for performing internal calibration using the built-in calibration weight.
Step-by-step guide for performing external calibration using user-provided weights.
Steps to activate the menu for setting IDs, time, date, and display brightness.
Explains F and CF keys for activating and managing the Animal Weighing/Averaging program.
Provides a table of display errors, their causes, and recommended solutions for resolution.
Recommends professional servicing and repairs by trained technicians to maintain performance and safety.
Operator responsibility for modifications, connections, and minimum operating specifications.
Step-by-step guide for assembling the analytical draft shield chamber components.
Instructions for fitting and securing the 3-sided draft shield onto the balance.
Specific steps for connecting the AC adapter to CP225D and other balance models with different weighing capacities.
Specific instructions for leveling balances with a weighing capacity up to 10 kg using the front feet.
Detailed description of the balance/scale's display indicators and physical operating keys/buttons.
Steps for preparing the balance/scale, including turning it on and taring.
Important note regarding the use of the under-balance weighing port with legal measuring instruments.
Requirements for internal calibration of verified instruments after warmup before legal use.
Describes the sequence for calibration/adjustment and available factory settings for modes.
Step-by-step guide for performing internal calibration using the built-in calibration weight.
Step-by-step guide for performing external calibration using user-provided weights.
Steps to activate the menu for setting IDs, time, date, and display brightness.
Explains F and CF keys for activating and managing the Animal Weighing/Averaging program.
Provides a table of display errors, their causes, and recommended solutions for resolution.
Recommends professional servicing and repairs by trained technicians to maintain performance and safety.
| Capacity | 150 g |
|---|---|
| Readability | 0.001 g |
| Repeatability (Std. Dev.) | 0.001 g |
| Linearity | ±0.002 g |
| Calibration | External |
| Weighing Units | g, ct, oz, ozt, dwt, lb |
| Display | LCD |
| Power Supply | AC Adapter |
| Operating Temperature | +10°C to +30°C |
| Operating Humidity | Up to 85% RH, non-condensing |
| Interface | RS-232 |