2 APD-200 SATEL
Temperature measurement accuracy ................................................................................±1°C
Standby current consumption .......................................................................................... 70 µA
Maximum current consumption ........................................................................................12 mA
Detectable speed ...................................................................................................... 0.3...3 m/s
Warm-up period ..................................................................................................................35 s
Recommended installation height ............................................................................ 2 m...2.4 m
Coverage area ................................................................................................15 m x 24 m, 90°
Complied with standards..................................................EN50131-1, EN50130-4, EN50130-5
Security grade according to EN50131-2-2 (detector mounted directly to the wall)........ Grade 2
Environmental class according to EN50130-5 .........................................................................II
Operating temperature range...............................................................................-10°C...+55°C
Maximum humidity ..........................................................................................................93±3%
Dimensions ................................................................................................... 62 x 137 x 42 mm
Weight...............................................................................................................................132 g
3 Description
Radio communication
The detector connects to the controller / control panel at regular time intervals to provide
information about its state (periodical communication). Additional communication may take
place as a result of alarm (see “Operating modes”).
Alarms
The detector will report alarm:
after detecting a motion in the protected area,
after detecting a fault in the motion detection system,
after opening the tamper switch (tamper alarm).
Operating modes
Active – information about tamper alarm and motion detection alarm is sent immediately.
Passive – only information about tamper alarm is sent immediately. This operating mode
prolongs the battery life.
The detector operating mode is turned on remotely. If the detector is used in the INTEGRA /
VERSA alarm system, the operating mode may depend on the partition state (partition
disarmed – passive mode; partition armed – active mode). For more information, refer to the
ABAX 2 / ABAX controller manual / the INTEGRA 128-WRL control panel manual.
Energy saving mode (ECO)
If you want to prolong the battery life, you can enable in the detector the “ECO” option. When
the “ECO” option is enabled, the periodical communication takes place every 3 minutes. Thus
the battery life can be increased as much as fourfold. The option is only available in the
ABAX 2 system. The detector with “ECO” option enabled meets requirements of the
EN50131-2-2 standard for Grade 2.
Test mode
The test mode makes the detector testing easier, because the LED indicators are enabled.
How to start and end the test mode is described in the ABAX 2 / ABAX controller manual /
the INTEGRA 128-WRL control panel manual.