SATEL AXD-200 5
• Occupies 2 positions on the device list (optionally 1 – only the roller shutter input is
supported – terminal M2).
2 Description
Radio communication
The detector connects to the controller / control panel at regular time intervals to provide
information about its state (periodical communication). Additional communication may take
place as a result of alarm (see “Operating modes”).
Alarms
Described below are circumstances in which the detector reports alarm, depending on the
detector type. Irrespective of the detector type, tamper alarm is reported on opening the
tamper contact.
AMD-200 / AMD-201
The detector will report alarm:
• after moving the magnet away from the detector (opening the window or door),
• after opening the NC type input.
AMD-202
The detector will report alarm:
• after moving the magnet away from the detector (opening the window or door),
• after opening the NC type input,
• after registering the specified number of pulses within a defined time period by the roller
shutter input,
• after opening the roller shutter input (tamper alarm).
AVD-200
The detector will report alarm:
• after detecting a shock caused by impact,
• after moving the magnet away from the detector (opening the window or door),
• after opening the NC type input.
ARD-200
The detector reports alarm when it senses a change in its position. The detector remembers
position at the moment of being switched into active mode or starting the test mode. Fig. 1
shows the changes in orientation that can be sensed by the detector.