ETHM-1 Plus
ETHERNET COMMUNICATION MODULE
ethm1_plus_sii_en 06/16
Quick installation guide
Full manual is available on www.satel.eu
The ETHM-1 Plus module enables the INTEGRA Plus, INTEGRA and VERSA alarm control
panels to communicate via the Ethernet network.
1. Electronics Board
Fig. 1. Module electronics board.
terminals:
+12V - +12 V DC power input.
COM - common ground.
TMP - tamper input (NC) – if not used, it should be shorted to common ground.
A RS485 B - terminals provided for future applications (RS-485).
DTM - data (communication bus).
CKM - clock (communication bus).
RS-232 port.
PWR/LOG LED:
OK – power OK,

Other manuals for Satel ETHM-1 Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Satel ETHM-1 Plus and is the answer not in the manual?

Satel ETHM-1 Plus Specifications

Power IconPower
supply voltage12 V DC ±15%
standby current consumption70 mA
maximum current consumption80 mA
Operating Environment IconOperating Environment
environmental classII
operating temperature range-10 to +55 °C
maximum humidity93±3%
Weight and Dimensions IconWeight and Dimensions
dimensions68 x 140 mm
weight64 g