9
Setting (For SK-8110)
1. Press the button for more than 3 seconds to enter the
emissivity setting mode. The LCD displays the previously set
emissivity value.
2. Press the button to display emissivity value.
Select the appropriate emissivity among 0.95, 0.90 and 0.85.
0.95 : Food such as meat, fish and vegetables
0.90 : Cardboard containers
0.85 : Grills and iron plates
3. Press the button for more than 1 second. After the
measurement, the selected emissivity is registered.
Setting (For SK-8120 / SK-8130 / SK-8140)
1. Press the button for more than 3 seconds to enter the
emissivity setting mode. The LCD displays the previously set
emissivity value.
2. Refer to No. 4 when change the emissivity. If you skip the
setting of emissivity, press button a few time to
display the setting mode you need.
3. The setting mode can be switch cyclically as shown in the figure below.
(SK-8120)
(SK-8130/SK-8140)