KDB-GOM
Series
- 90 -
No 12 Part name High limit sensor
Replacement steps
Disassembly
①
Unplug the boiler form the electric outlet.
②
Open the front cover.
③
Separate the overheating prevention device’s two terminals (red).
④
Remove the clip fixing the overheating prevention device ( or unscrew the two screws ).
⑤
Separate the overheating prevention device.
Assembly
①
Fix the overheating prevention device by inserting the clip (or screw the two screws ).
②
Connect the overheating prevention device wire.
③
Close the front cover.
④
Plug the boiler into the electric outlet.
Caution
1. Make sure fixation is done correctly.
2. Make sure the connecting jack is assembled correctly.
⑤
④