KDB-GOM
Series
- 96 -
No 17 Part name Power transformer
Replacement steps
Disassembly
①
Unplug the boiler from the electric outlet.
②
Open the front cover.
③
Separate the harness jack connecting the power transformer and the controller.
④
Unscrew the 2 screws fixing the power transformer and separate it from the boiler.
Assembly
①
Fix the power transformer to the boiler by screwing the 2 screws.
②
Put the power transformer harness jack into the controller.
③
Plug the power cord into the outlet and check its operation. If everything is fine, close the front cover.
④
Plug the boiler power cord into the outlet.
Caution
Make sure the connecting jack is connected properly.
④