TECHNICAL DATA
3
Installation
The house owner is responsible for ensuring that all necessary nati-
onal and local safety measures are observed during installation and
fitting and also responsible for observing the fitting and operating
instructions detailed in this manual.
When you install any kind of fireplace or stove, you must inform the
local authorities. You are also responsible for calling in a chimney
sweep to inspect and authorize the installation.
To ensure best-possible functionality and safety for your installa-
tion, we advise you to call a professional fitter. Our Scan Dealer will
be able to recommend a qualified fitter in your area. For information
on Scan Dealers, please go to www.scan.dk.
Safety
Any changes made to the product by the dealer, installer or user
could result in the product and safety functions not functioning
as intended. The same applies to the fitting of accessories or extra
equipment not supplied by Scan A/S. This could also be the case if
parts that are necessary for the operation and safety of the stove are
dismantled or removed.
Technical data and dimensions
CO Emission at 13% O
2
: 0,10% 1209 mg/Nm
3
Dust @ 13% O
2
: 42 mg/Nm
3
No
x
@ 13% O
2
: 114 mg/Nm
3
Efficiency: 79%
Rated heat load: 7 kW
Chimney temperature: 290 °C
Flue outlet flow: 8 g/sec
Vacuum EN 13240: 12 Pa
Recommended vacuum in flue collar: 16-20 Pa
Combustion air requirement: 21 Nm
3
/h
Recommended fuel: Wood
Fuel consumption: 2,25 Kg/h
Amount of fuel: 1,7 kg
Weight: Scan 53: 160 kg
Flue collar internal diameter: 135 mm
Flue collar external diameter: 148 mm
Approval type: Intermittent fuelling
Intermittent fuelling means normal use of a woodstove. In other
words, you should let the fire die down until only the embers are
left, before refuelling.
The Scan 53 was build in compliance with the homologized product
type specified in the Assembly- and Instructions Manual provided
with the product.