hurrySCAN
®
10, digital, 1064 nm, f = 254 mm
Rev. 2.6 e
8 Troubleshooting
33
innovators for industry
8 Troubleshooting
If problems occur while operating this device, verify
that all operating instructions have been adhered to
and then carry out the following troubleshooting
procedures:
If the problems persist, please send the scan head to
customer service.
Problem Possible Cause Remedy
Low laser power Dirty objective Clean as described in "Routine
Maintenance of the Optical
Surfaces" on page 31
Altered controller software
parameters
Check input parameters
Dirty or damaged mirror Check mirrors. If they are
contaminated, call SCANLAB for
guidance. Return damaged scan
head mirrors for repair.
Changed laser spot Dirty or damaged objective Clean as described in "Routine
Maintenance of the Optical
Surfaces" on page 31
Dirty or damaged mirror Check mirrors. If they are
contaminated, call SCANLAB for
guidance. Return damaged scan
head mirrors for repair.
Laser out of adjustment Adjust laser
No laser beam Problem with the laser Check laser and electrical
connections
Problem with the laser controller If the RTC
®
board is used, check all
electrical connections and the
power supply
Laser beam path blocked or shutter
closed
Check laser beam path
Scan head does not steer laser
beam in one or both directions
Problem with the scan head
controller
Check power and data cables.
Check software commands.