Installation instructions for adapter AD 01...03
5
Date: 01.08.2012
822.371 BA / EN
F An additional fog light (fuse: 5 A)
F Two devices that can be connected v ia a s eparate control input (input 1,
see Appendix E) -- fuse: 15 A
F One device that can be connected via a separate control input (input 4,
see Appendix E) -- fuse: 15 A
Connections and setting options are provided for:
F Additional position lights (fuse: 5 A)
F D+ Active +12 V, 2 A, (regardless of whether input is ”active +12 V” or
”active GND”)
F Switchover D+ ”active +12 V” or ”active GND”
F Switchover position lights ON with ”active +12 V” or ”active GND”
F Supply (7.5 A) daytime driving light is switched off by switching on the
low-beam light
F Additional outputs term. 15 (15 A)
F Additional outputs term. 30 (15 A)
12V outputs may only be loaded up to a maximum of 90% of the rated cur-
rent of the associated fuse (see block diagram or nameplate).
All consumers together may not exceed the following load (dependent on the
fuse on the vehicle battery):
F 45 A
AD 03
Current-carrying
capacity
Max. total current