Operating manual f o r caravan-charging system CSV 410
10
Date: 20.02.2020 8050102 BA / EN
5.4 Faults
A fault in the power supply system is usually caused by a blown fuse.
Please contact our customer service address if you cannot rectify the fault
using the following table.
If this is not possible, e.g. if you are abroad, you can have the caravan char-
ging system repaired at a specialist workshop. In this case, you must ensure
that the warranty is not invalidated by incorrect repairs being carried out.
Schaudt GmbH will not accept any liability for damage resulting from such
repairs.
Fault Possible cause Remedy
Caravan battery is not
No mains voltage Switch on the automatic
charged during 230 V
circuit breaker in the vehi-
-
-
tage
Defective caravan char-
ging system
Call customer service
Caravan battery is not
Defective alternator Check the alternator
charged whilst driving
No voltage applied to
Check the fuse and wiring
βIgnition ONβ input or per-
manent plus
Check the towing vehicle
plug connection
Defective caravan char-
ging system
Call customer service
Solar charger is not wor- Solar charge regulator not Plug in solar charge regu-
king (mains supply off)
plugged in
lator
e
ect
ve
use or w
r
ng
ec
use an
w
r
ng
Solar charge regulator de-
fective
Check solar charge regu-
lator
supp
y
oes no
wor
ma
nsw
c
ssw
-
ma
nsw
c
mus
e
in the living area ched o
switched on
e
ect
ve
use or w
r
ng
ec
use an
w
r
ng
Defective caravan char-
ging system
Call customer service
Caravan charging system Defective caravan char- Call customer service
cannot be switched on
ging system
using the rocker switch
No supply voltage Check the battery or
mains c onnection
Rocker switch is defective Call customer service
Pump will not switch on 12V main switch is swit-
ched off
12V main switch must be
switched on
Pump switch disabled Turn on pump switch
For immersion pumps:
Contact in the water tap of
pump defective
Contact a dealer.
For pressure pumps: Pres-
sure switch or pump de-
fective
Contact a dealer.
Flat vehicle fuses