811.598 BA / EN Situation: 25.06.2010 5
Instruction Manual Electrobloc EBL 269
4 Suitable accessories (not supplied)
Control and switch panel IT 269-3, LT 300
Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current
Additional 2-pin charging cable, lengths supplied on request
Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur-
rent of 14 A incl. 0.5 m connection cable and connector plug
5 Electrical data
6 Operation
6.1 Operating controls
Flat vehicle fuses
The flat vehicle fuses protect the various circuits.
Start up the system
Switch on the system using the 12 V main switch at the control and switch
panel. Follow the instruction manual of the control and switch panel.
Shutting down the system
Switch off the system using the 12 V main switch at the control and switch panel.
Type no. Fuse value
911.520 2.5 A slow blow
911.525 2.5 A slow blow
911.521 3.15 A slow blow
911.526 3.15 A slow blow
Mains connection 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I
Suitable batteries 6-cell lead acid or lead gel batteries of at least 55 Ah
Current-carrying capacity 12 V outputs No more than 90 % of the rated current
of the appropriate fuse may be drawn,
see the block diagram.
Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
Never bridge or repair fuses.
Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
Only use original fuses rated as specified in the instruction manual.
Before starting up:
Make sure the living area battery is connected.
Make sure the battery selector switch is set for the correct type of bat-
tery.
Make sure the AES fuse is only used if the compressor/AES refrigera-
tor is connected. Otherwise, the living area battery may get totally dis-
charged. Battery damage is possible.