811.598 BA / EN Situation: 25.06.2010 5
Instruction Manual Electrobloc EBL 269
4 Suitable accessories (not supplied)
Control and switch panel IT 269-3, LT 300
Auxiliary charging unit Schaudt battery charging unit type LAS... with up to 18 A charge current
Additional 2-pin charging cable, lengths supplied on request
Solar charge regulator Schaudt solar charge regulator type LR... for solar modules with a total cur-
rent of 14 A incl. 0.5 m connection cable and connector plug
5 Electrical data
6 Operation
6.1 Operating controls
Flat vehicle fuses
The flat vehicle fuses protect the various circuits.
Start up the system
Switch on the system using the 12 V main switch at the control and switch
panel. Follow the instruction manual of the control and switch panel.
Shutting down the system
Switch off the system using the 12 V main switch at the control and switch panel.
Type no. Fuse value
911.520 2.5 A slow blow
911.525 2.5 A slow blow
911.521 3.15 A slow blow
911.526 3.15 A slow blow
Mains connection 230 V AC ± 10 %, 47 to 63 Hz sinusoidal, protection class I
Suitable batteries 6-cell lead acid or lead gel batteries of at least 55 Ah
Current-carrying capacity 12 V outputs No more than 90 % of the rated current
of the appropriate fuse may be drawn,
see the block diagram.
▲ Blown fuses must only be replaced when the cause of the fault is
known and eliminated.
▲ Never bridge or repair fuses.
▲ Danger of burning! Blown fuses must only be changed on a zero-cur-
rent Electrobloc.
▲ Only use original fuses rated as specified in the instruction manual.
▲ Before starting up:
●
Make sure the living area battery is connected.
●
Make sure the battery selector switch is set for the correct type of bat-
tery.
●
Make sure the AES fuse is only used if the compressor/AES refrigera-
tor is connected. Otherwise, the living area battery may get totally dis-
charged. Battery damage is possible.