SDT-0054-00EN Situation: 15.06.2005 9
Instruction Manual Electrobloc EBL 99 G
10 Technical faults, possible causes and remedies
If you are unable to solve a fault using the following tables, please contact our
customer service address.
If this is not possible, e. g. if you are abroad, you can have the Electrobloc
repaired at a specialist workshop.
Inexpert repairs invalidate the guarantee for the Electrobloc and Schaudt
GmbH takes no liability for any resulting damage.
Fault Possible cause Remedy
Living area battery is not
charged during 230 V
operation (battery voltage
constantly below 13.3 V)
No mains voltage Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Defective Electrobloc Call customer service
Living area battery is over-
charged during 230 V
operation (battery voltage
constantly above 14.5 V)
Defective Electrobloc Call customer service
Starter battery is not
charged during 230 V
operation (battery voltage
constantly below 13.0 V)
No mains voltage Switch on the automatic
fuse in the vehicle
Have the mains voltage
checked
Defective Electrobloc Call customer service
Living area battery is not
charged during mobile
operation (battery voltage
below 13.0 V)
Defective alternator Have the alternator
checked
No voltage at D+ input Have the fuse and wiring
checked
Defective Electrobloc Call customer service
The living area battery is
overcharged during mobile
operation (battery voltage
constantly above 14.3 V)
Defective alternator Have the alternator
checked
The refrigerator does not
work during mobile opera-
tion
No power supply to the
refrigerator
Have the fuse and wiring
checked
Defective Electrobloc Call customer service
Defective refrigerator Have the refrigerator
checked
Solar charger does not
work (power supply and
engine are off)
Solar charge regulator not
plugged in
Plug in the solar charge
regulator
Defective fuse or wiring Have the fuse and wiring
checked
Defective solar charge reg-
ulator
Have the solar charge reg-
ulator checked