10
The Yellow Charging LED is ON (if above situation occurred)
o Float Mode (Safe voltage level of 13.6V)
Full Green LED is ON.
The Float Mode allows the charger to effectively be left connected to your
batteries; it works at a safe level of 13.6V, and ready for use.
o Maintenance mode (Special pulse for long term maintenance)
Full Green LED is ON.
The program engages a special charging waveform and monitors the battery
voltage variety, if the battery voltage sinks, the special pulses will keep the
battery in optimal state, if the battery voltage drops even lower, the battery
charger will switch into Bulk charging stage. The maintenance mode allows
the charger can be connected to the battery over the course of a season; if
possible; check the electrolyte liquid level in the battery.
STEP 4 - Disconnecting the Battery charger from Battery
If the Battery is out of the vehicle.
o Switch OFF and Remove the AC Power Plug from the outlet.
o Remove the Black lead and then the Red lead.
o Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)
If the Battery is in the vehicle.
o Switch OFF and Remove the AC Power Plug from the outlet.
o Remove the lead from the vehicle chassis.
o Remove the lead from the battery.
o Check electrolyte levels if possible.
(As they may need topping up with distilled water after charging)