Troubleshooting
Problem Possible Cause Help
Compressed air device does not
start or lacks power
Piston jammed (rusted) in the housing
due to a lack of oil
Press the piston back with a striking bolt
through the tool receiver
Introduce a little oil into the connection
hose and into the tool receiver
Run the device briey without a tool
Repeat this process a few times
Dirt has penetrated via the air hose
Repair must be carried out by a specialist
workshop
Too much lubricating oil used or water
in the striking mechanism
Run the device briey without a tool
Pressing force too high
Grease tool receiver and reduce pressing
force
Output power of the air source too low Use an air source with a higher output power
Tool no longer latches into the tool
receiver or does not lock into place
Tool or tool receiver worn out. (Most
often caused by excessive pressure or
no-load strokes)
Repair must be carried out by a specialist
workshop
Tool cannot be inserted or re-
moved
Dirt in the sliding sleeve prevents
unlocking
Repair/cleaning must be carried out by a
specialist workshop
Device operates continuously with-
out the trigger lever being actuated
Valve defective
Repair must be carried out by a specialist
workshop
End of work
Interrupt the compressed air supply from the com-
pressed air hose to the device.
With breaks in work:
Place the compressed air device safely to one side.
If there are sharp or pointed tools in the device, cover
these up.
At the end of work:
Interrupt the compressed air supply.
Remove the tool from the device.
Check that the tool receiver has been furnished with
an oil lm.
If this is not the case, introduce a few drops of special
oil into the connection hose and operate the device
without tool for ca. 15 seconds.
Clean the compressed air device, the tools, the hose
and any other accessories with a dry or oily, clean
cloth.
Maintenance and care
If the regular oil supply to the device is assured, the
device is maintenance-free.
Clean the device at regular intervals.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consuma-
bles.
Wear parts*: Application tools
* Not necessarily included in the scope of delivery!
Storage
Note
Store the device in a dry and frost-free location (10-
25 °C).
Fertiliser and other garden chemicals contain sub-
stances that can have a severely corrosive effect on
the metal parts. Do not store the device in the vicinity
of these substances.
Disposal and recycling
The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material and
can therefore be reused or can be returned to the raw
material system. The unit and its accessories are made
of various types of material, such as metal and plastic.
Defective components must be disposed of as special
waste. Ask your dealer or your local council.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scheppach Aero2 Spade and is the answer not in the manual?

Scheppach Aero2 Spade Specifications

General IconGeneral
BrandScheppach
ModelAero2 Spade
CategoryNail Gun
LanguageEnglish

Related product manuals