Dual-channel design with monitored, positive guided contacts and four green LEDs for status indication.
Connect safety switches to S13-S14 and S23-S24; release contact to X2-X3 or X1-X2.
Three NO contacts for authorized operation and one NO contact for signal path.
AZR31R2 checks internal contacts, uses reset input for release, and handles input interruption/short circuits.
AZR31T2 checks internal contacts, uses feedback input for release, and handles input interruption/short circuits.
Wiring examples for AZR31R2 (manual reset) and AZR31T2 (feedback control) with emergency stops.
Wiring example for AZR31R2 using two-hand operation panels requiring simultaneous button presses.
Wiring examples for AZR31R2 (manual reset) and AZR31T2 (feedback control) with safety doors.
Wiring examples for AZR31R2 (manual reset) and AZR31T2 (feedback control) with safety mats/edges.
Describes the meaning of the ON, IN A, IN B, and OUT LEDs when illuminated.
Describes the meaning of the ON, IN A, IN B, and OUT LEDs when not illuminated.
Details compliance with regulations, housing material, mounting, and protection class.
Covers operating voltage, power rating, inputs, outputs, and switching capabilities.
Specifies switch-on/off times, connection sizes, operating temperature, weight, and approvals.
Dual-channel design with monitored, positive guided contacts and four green LEDs for status indication.
Connect safety switches to S13-S14 and S23-S24; release contact to X2-X3 or X1-X2.
Three NO contacts for authorized operation and one NO contact for signal path.
AZR31R2 checks internal contacts, uses reset input for release, and handles input interruption/short circuits.
AZR31T2 checks internal contacts, uses feedback input for release, and handles input interruption/short circuits.
Wiring examples for AZR31R2 (manual reset) and AZR31T2 (feedback control) with emergency stops.
Wiring example for AZR31R2 using two-hand operation panels requiring simultaneous button presses.
Wiring examples for AZR31R2 (manual reset) and AZR31T2 (feedback control) with safety doors.
Wiring examples for AZR31R2 (manual reset) and AZR31T2 (feedback control) with safety mats/edges.
Describes the meaning of the ON, IN A, IN B, and OUT LEDs when illuminated.
Describes the meaning of the ON, IN A, IN B, and OUT LEDs when not illuminated.
Details compliance with regulations, housing material, mounting, and protection class.
Covers operating voltage, power rating, inputs, outputs, and switching capabilities.
Specifies switch-on/off times, connection sizes, operating temperature, weight, and approvals.
| Product name | AZR31R2 |
|---|---|
| Input Voltage | 24 VDC |
| Output Type | Relay |
| Switching current | 6 A |
| Category | Control Unit |
| Operating voltage | 24 VDC |