5.3 Operating the unit
1.)Place the restoration in the fluid in the plastic vessel and close the lid tightly.
2.)In order to avoid rotation of the cleaning vessel, set a paper towel between unit and black
beaker mount (acrylic top).
3.)Place the vessel on the unit.
4.)Set the timer to the correct time. The magnetic field rotates in direction.
5.)Once the time has elapsed, the unit switches off automatically. Remove the lid
from the vessel, remove the restoration and rinse it with water. If the outcome
is not satisfactory, prolong the time.
6.)Contaminated cleaning fluid should be disposed of according to local
regulations, making certain to keep the pins. Rinse the pins with clear water
and fresh polishing fluid.
Please note!
This unit can be switched off prematurely at any time with the timer.
6 Maintenance/Servicing
Danger!
Before commencing maintenance procedures or replacing components the
unit must be switched off as follows.
Disconnect the current as follows:
• Switch the timer off
• Unplug the mains supply
In case of non-compliance, the staff's life and limbs may be at a risk!
• This unit should be cleaned with a damp cloth or stainless steel cleaner.
• Clean the vessels regularly and thoroughly.
Please note!
Do not clean with solvent as it may harm the plastic components.