Depending on the regular operation of the
machine, the StepOne may require the AC wall
pack to be plugged into the machine at all times.
1. A full step stride of 11.5” below 40 Steps per Min.
2. A half step stride of 6” below 80 Step per Minute
Position the unit in a location that has a stable and level
sub-oor. Equipment should be positioned in a location
that is not in direct sunlight, extreme temperatures and
humidity or where it may be splashed with water or uids.
1m
Spacing
SPECIFICATIONS
Endcap
Endcap
1m
Spacing
1m
Spacing
1m
Spacing
Offset Endcap
Additional personnel may be required to move the machine.
Placement on an unstable sub-oor without a proper safety
perimeter can result in injury to yourself and others.
The StepOne has two transport wheels located in the front
of the machine and can be moved by grabbing the lift handle
at the rear of the machine.
LIFT
HANDLE
The StepOne should be positioned with a safety perimeter
of 1 meter around the unit (see diagram).
If the sub-oor is unlevel, the unit is equipped with leveling
end caps. The end caps are designed with the recess of the
end cap off centered. This allows you to rotate the endcap(s)
to a position that will level the equipment. After adjustment,
check and make sure end caps are fully seated against base
frame tubes.
SCIFIT Scientic Solutions For Fitness SCIFIT Scientic Solutions For Fitness SCIFIT