Electrical
See the spec sheet or User's Manual for Minimum Circuit Ampacity or Maximum Fuse Size
ratings.
The machine is not supplied with a power cord, one must either be field installed or the
machine hard-wired.
The dataplate on the back of the cabinet details the power requirements, including voltage,
phase, minimum circuit ampacity and maximum fuse size. HACR type circuit breakers may be
used in place of fuses. Extension cords are not permitted. Use of a licensed electrician is
recommended.
Electrical connections are made inside the junction box in the back panel of the ice machine.
Follow all applicable local, state and national codes.
September 2006 Page 6
General Installation - Air or Water Cooled