FOR THE INSTALLER: Specifications
MDT5N25 & MDT5N40
August 2010
Page 2
14.06"
1.88"dia
20.5"
22.5"
2.56"
Optional for water and
drain lines
Serial Number Plate
inside on upper base
below control box.
ELECTRICAL JUNCTION BOX
3/8" FPT
condenser
Water Inlet
(Water Cooled)
1/2" FPT
Cond. Drain
(Water Cooled)
12.27"
1.12"
3.12"
5.12"
6.43"
4.5"
3.54"
3/8" Flare
Potable Water Inlet
NAMEPLATE
on back panel
SPECIFICATIONS
Model Number Dimensions (w/o stand)
H”xW”xD”
Basic
Electric
Cond.
Type
Ref. Charge,
R-404A in ounces*
Minimum Circuit
Ampacity
Maximum
Fuse Size
MDT5N40A-1J 48.5 x 26 x 22.5 115/60/1 Air 24 19.3 25
MDT5N40W-1J 48.5 x 26 x 22.5 115/60/1 Water 17 17.8 20
MDT5N25A-1J 41 x 26 x 22.5 115/60/1 Air 24 19.3 25
MDT5N25W-1J 41 x 26 x 22.5 115/60/1 Water 17 17.8 20
MDT5N40A-1B 48.5 x 26 x 22.5 115/60/1 Air 24 19.3 25
MDT5N40W-1A same 115/60/1 Water 18 17.8 20
MDT5N40W-1B same 115/60/1 Water 17 17.8 20
MDT5N40A-6B same 230/50/1 Air 24 11 15
MDT5N40W-6A same 230/50/1 Water 18 10.4 15
MDT5N40W-6B same 230/50/1 Water 17 10.4 15
MDT5N25A-1B 41 x 26 x 22.5 115/60/1 Air 24 19.3 25
MDT5N25W-1A same 115/60/1 Water 18 17.8 20
MDT5N25W-1B same 115/60/1 Water 17 17.8 20
MDT5N25A-6B same 230/50/1 Air 24 11 15
MDT5N25W-6A same 230/50/1 Water 18 11 15
MDT5N25W-6B same 230/50/1 Water 17 11 15
* Refrigerant charge change between A and B water cooled. Always check the nameplate for charge info.
3/4" FPT
Drain