For a longer freezing
cycle change the
combination of the DIP
SWITCH from 9 to 11
minutes.
New combination for 11
minutes Time Ta is:
OFF-ON-OFF-ON
1 2 3 4 Ta min.
OFF OFF ON ON 7
ON ON OFF ON 9
OFF ON OFF ON 11
ON OFF OFF ON 13