7.COUNT
7.1 Average Piece Weight Setting
Put a container for parts on the platter or not (if not necessary), press
[COU/AFF], the scale will display "10" (flashing), then put 10 pcs parts
on the container or platter, press [COU/AFF]to confirm, the scale will
enter into waiting mode by displaying "------" for a while, then it will
display "10" to finish average piece weight setting.
Average pieces are available: press [TAR/CAL]to choose average piece
from "10,20,50,100,200,500", other process is the same as above.
7.2 COUNT OPERATION
7.2.1 Put parts to be counted on the platter, press [COU/AFF], the scale
will display piece number.
7.2.2 Press [COU/AFF] again to exit from counting mode.
8.OVERLOAD ALARM
If the loading weight is larger than (1+0.2%) of full capacity, the scale
will display "- - - - - -", meaning overload. Take off the goods
immediately to avoid damaging the scale.
8. Power-saving
When the weighing mode is stable, the scale will automatically turn off
the backlight to enter into auto power-saving status. When the weighing
is unstable, the backlight will turn on automatically.