Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
1) Product description
This is a dual channel keypad that is activated only after having entered a suitable combination.
The units are designed for indoor or outdoor installations.
The estimated transmission range is 200 m in open spaces and 35 m indoor.
The units are designed to ensure battery life equivalent to an estimated of 2 years of operation considering 10 transmissions/day.
Audible signal Status
2) Installation
Before physically installing the keypad in its mouning position it is good practice to perform a practical test to assess its functionality and effective
range.
2.1) Positioning
Apart from the distance from the receiver, the unit should not be positioned in contact with metal structures, which could otherwise exert a signal
shielding effect.
Thanks to the box protection rating of IP 54, the digital keypads can be installed on the outside if required.
3) Method of use
The use of the keypad is based on "combinations", i.e. numbers of, from 1 to 9 digits, that the user is required to key in by means of the keys. Once
the combination has been entered the user then presses the confirm key or to transmit the activation command to, respectively:
-receiver channel 1 if the user presses
-receiver channel 2 if the user presses
The command will be transmitted only when a valid combination has been entered
- if the entered combination is wrong the selector will emit an error waming signal when the confirm key is pressed. The combination entered must
be exact, if for example, the combination is 0422, the following attempts will be interpreted as errors: 422, 10422, 04222. Therefore, if the user
inadvertently presses the wrong key when entering a combination, combination key or should be pressed immediately to generate the error
tone, after which the correct combination can be entered starting from the beginning again.
While entering the combination no more than 6 seconds can be allowed to elapse between keystrokes, otehrwise the combination must be re-
entered starting from the beginning.
The units are factory programmed with a standard combination to activate channel one and a standard cornbination for channel two.
The factory set combinations are as follows:
a
1 combination to transmit the code associated with key.
When the unit is used for the first time this combination is 11
a
2 combination to transmit the code associated with the key.
When the unit is used for the first time this combination is 22.
4) Changing a combination
Tab.A Changing the combination associated with channeI 1 Example
This function allows you to change the combination associated with channel 1
1. Press the "0" key and hold it down while pressing and releasing (0 )
2.Release the "0" key .
Consider that range may be up to 25 or 30% less when battery is low or in the presence of metal structures. The keypad should be stored in a
receiver compatible with a standard transmitter, pressing the control buttons. For more details refer to the manual of the used receiver.
Rev.00 - 09/2012
English
1 short beep Keypad tone
1 long beep Auto power-off
3 long beeps Modification of combination confirmed
5 short beeps Error during combination input or combination edit operation
l0 rapid beeps Battery low warning signal new batteries required
SEA S.p.A.
Zona industriale 64020 S.ATTO Teramo - (ITALY)
Tel. +39 0861 588341 r.a. Fax +39 0861 588344
www.seateam.com seacom@seateam.com
67411470
ROCK
Wireless keypad (23105196)
2XCR2032 (6V)
12 bit fix code
2
433.920Mhz
-20°C +60°C
-30°C +80°C
84x74x37
from 5% to 90% no condensation
Technical Characteristics
Power supply
Encoding
Channels
Frequency
Working Temperature
Warehousing Temperature
Dimensions
Humidity
3