Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
5.8. Mufer screen and spark arrester.
WARNING!Theengineandmuferwillbeveryhotaftertheenginehasbeenrun.Avoidtouchingtheengineandmuferwhilethey
are still hot.
5.8.1. Loosen the cover and remove.
5.8.2. Loosentheboltsthenremovethemufercap,themuferscreenandsparkarrester.
5.8.3. Cleanthecarbondepositsonthemuferscreenandsparkarresterusingawirebrush.
Brush gently to avoid damage to the component.
5.8.4. Checkthemuferscreenandsparkarrester.Replaceifdamaged.
5.8.5. Install the spark arrester.
5.8.6. Installthemuferscreenandthemufercap.
5.8.7. Install the cover and tighten the screws.
5.9. Fuel tank lter
5.9.1. Removethetankcapandlter.
5.9.2. Cleanthelterwithpetrol.
5.9.3. Wipethelterandinstallit.
5.9.4. Replace the fuel tank cap. Be sure the fuel tank cap is tightened securely.
5.10. Fuel Filter
5.10.1. Thefuellterislocatedinthefuelpipeleadingfromthefueltanktothecarburettor.
5.10.2. Drain fuel from fuel tank.
5.10.3. Squeezethepipeclampsandremovethelter.
5.10.4. Replacethelter.
5.10.5. Attach the fuel pipes and re-clamp.
5.10.6. Check for any fuel leaks.
6. STORAGE
Long term storage of the generator will require preventive procedures to guard against deterioration.
6.1. Turn the engine switch to “STOP”.
6.2. Removefueltankcapandlter.
6.3. Extractthefuelfromthetankintoanapprovedfuelcontainer.Replacethefuellterandcap.
6.4. Wipe off any spilt fuel.
6.5. Start the engine and leave it to stop. (approx 20 min)
6.6. Drainthefuelfromthecarburettor,byremovingscrewontheoatchamber.Replacescrew.
6.7. Turn the engine switch to “STOP”.
6.8. Remove the spark plug, pour about one table-spoon of SAE 10W-30 into spark plug hole. Using the recoil starter turn over the engine
to coat the cylinder walls with oil.
6.9. Replace spark plug, pull the recoil starter until you feel compression. Then stop pulling. (This prevents the cylinder and valves from
rusting)
6.10. Clean exterior of the generator with a dry cloth. Store the generator in a dry, well-ventilated child proof area.
7. TROUBLESHOOTING
7.1. Fuel System:- Check fuel in tank, vent knob and fuel tap to “ON”
Checkfuellter,carburettor,cleanasrequired.
7.2. OilSystem:-Checkoillevel,llasrequired.
7.3. Electrical system:- Check/Clean spark plug
Faulty ignition system, Consult our authorized stockist.
7.4. No power produced:- Press the DC protector to “ON”
The AC pilot light (green) goes off, Stop the engine and then restart.
GI2300,GI3500Issue2(g1)19/04/18
Original Language Version
© Jack Sealey Limited