3.7. Determine the correct brake bleeding sequence from your vehicles service manual. Attach bleed tube to bleed valve at the rst
cylinder to be bled, open end in a suitable uid receptacle. Open bleed valve and bleed until uid runs clear and free of bubbles.
Tighten bleed valve to the torque specied in your vehicle service manual.
3.8. Repeat on each bleed valve. Pump additional pressure into bleeder if necessary.
3.9. If uid remains in the bleeder reservoir when nished, tip the tank away from uid pick up tube and open bleed valve closest to the
master cylinder. Allow air to ow into uid reservoir until uid level falls just to the maximum ll level on your reservoir. Close the
bleed valve and tighten to specied torque.
3.10. When complete, release pressure by slowly loosening the pump cap. Remove the cap from the uid reservoir, taking care to avoid
spilling any uid that remains in the tube.
3.11. Replace uid reservoir cap on your vehicle, checking that the uid level is at the maximum level indicated on the vehicle reservoir.
3.12. Before driving your vehicle, carefully check for leaks and test for proper brake operation.
8 DO NOT store hydraulic uid in bleeder. Always dispose of excess uid properly in accordance with local authority regulations.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Adaptor deployed
Vehicle
reservoir
Brake and clutch bleeding system-
Model No VS820.V4
90° elbow
connector
Universal Adaptor - Model No. VS820UA.
Straight Adaptor - Model No. VS820SA.
Original Language Version
© Jack Sealey Limited
VS820.V4 Issue 3 (2) 17/09/18
Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500