Important are only the first three characters Sxx for lift status and
Fxx for floor and file type .wav!
Configuration file
The configuration file is a text file and can be edited with Windows
Notepad. Settings in this file are shown in the local configuration except
for the “out of service” text and the floor display table.
1. my_floor
0 – Not active, travel direction is shown according to the controller
settings.
1..48 – PKN10 shows direction only when car is in the preset
station.
2. display_starts_at the floor
Default floor table is -2, -1, 0, 1, …, 48; display offset can be set with
this parameter. Setting 1 means that “-2” is displayed in the lowest
station; setting 2 means that “-1” is displayed in the lowest station
and so on. This function works with the changed floor table too, see
parameter “floor01..floor48”.
3. input1: Input I1 function definition (not active in PKN06 compatible
mode)
0 - Not active.
1 – Fire alarm door A.
2 – Fire alarm door B.
4. input2: Input I2 function definition (not active in PKN06 compatible
mode)
0 - Not active.
1 – Fire alarm door A.
2 – Fire alarm door B.
5. input3: Input I3 function definition (not active in PKN06 compatible
mode)
0 - Not active.
1 – Landing door control.
2 – Fire fighter key.