Model | EL-80-15 |
---|---|
Category | Water Pump |
Max Flow Rate | 80 l/min |
Voltage | N/A (Air operated) |
Rated Voltage | N/A (Air operated) |
Read manual, follow safety instructions, and use authorized service facilities.
Always disconnect power before servicing to avoid electric shock and injury.
Clean the air filter every 3 to 4 months for optimal pump performance.
Check airflow, noise, temperature, and power cord condition regularly.
Steps to remove, clean (wash with detergent), dry, and reinstall the filter element.
Remove outer covers, bushing, shock absorber, and holder cover for access.
Remove valve box, disconnect pipe, and remove/replace diaphragm using nut or bolt.
Install new valve box, replace diaphragm, check centering, reconnect pipe, and test.
Reinstall shock absorber, power cord bushing, overall cover, and air filter.
Explains the protective switch function and steps to reset the slider for auto stopper.
Procedure to replace diaphragm and magnet, ensuring correct orientation and centering.
Table listing problems, their causes, and recommended actions for pump issues.
Details voltage, frequency, pressure, flow, power, dimensions, and weight for different pump models.
Shows total and single resistance values for solenoids across different pump models.
Information on genuine SECOH replacement parts and recommended replacement intervals.