6
1. (Read Master Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Delete Card) to stop deleting.
6. Programming
Programming will vary depending on access configuration. Follow the instructions according to your access
configuration.
General Programming Information
Remote Control: Please use the Infrared Remote Control to program the Reader.
User ID number:Assign a user ID to the access card in order to track it. The user ID number can
be any number from 1~1000.
IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User
ID is crical. Modifications to the user require the User ID be available.
6.1 Basic Configuration
6.1.1 Enter and Exit Program mode
* (Master Code) #
(Factory default is 123456)
6.1.2 Set Master Code
0 (New Master Code) # (Repeat New Master Code)
#
(Master code is any 6 digits)
6.2 Add User Cards