Note: To use this function, you need to change the recording mode to configuration and
set the effective time period and start the detection recording in [Main Menu] > [Recording
Function] > [Recording Settings].
“Tour”: Set the channel number of the full-screen display when the motion detection alarm
is triggered (can be checked); when the alarm occurs, the recorder will cycle the
full-screen display of the selected channel;
Note: The interval between the full screen display of the selected channel during the tour
process is set in [Main Menu] > [System Settings] > [Tour Settings];
“PTZ Activation”: Set the recorder to call the preset point of the selected channel pan/tilt
when the alarm occurs, and cruise or patrol between points;
Note: In the analog channel mode and the analog channel in the hybrid channel mode, the
PTZ linkage is the camera PTZ corresponding to the analog channel. In the network
channel, the PTZ linkage is the PTZ of the front-end network camera corresponding to the
channel. Before connecting the PTZ, you need to set the PTZ preset point, inter-point
cruise, interval time and other parameters in [Quick Menu] > [PTZ Control]; the analog
channel needs to be connected to the RS485 control line.
“Show Message”: Set the recorder to pop up the alarm information dialog box in the local
preview screen such as VGA, HDMI, etc. when the alarm is triggered;
“Send Email”: When this function is enabled, the recorder sends an alarm email to the
specified mailbox when the motion detection alarm is triggered.
Note: Before using this function, you need to set the Outbox and Inbox in [Main Menu] >
[System Settings] > [Network Service] > [Email] and ask the recorder to connect to the
Outbox Server.
“FTP upload”: When this function is enabled, the recorder will upload an alarm video or
picture to the specified FTP server when the motion detection alarm is triggered.
Note: Before using this function, you need to set the FTP server to be used in [Main
Menu] > [System Settings] > [Network Service] > [FTP] and ask the recorder to connect to
the FTP server.
“Buzzer”: When the recorder is set to trigger an alarm, the buzzer on the local host of the
recorder issues a “beep” sound;