EasyManua.ls Logo

Secumore G03 - Set Time Interval Upload to Server; Disable fuel or electricity; Resume the Oil and Power System; Set All Alarm Command

Secumore G03
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
6.6 Set Time Interval Upload to Server
Send SMS commandITV+password+space+upload time interval to the
tracker device.
For example: send SMS ITV123456 10 it will report data to server at 10s time
interval.
6.7 Disable fuel or elecreicity
Send SMS command DY+password+space+1 to the tracker, it will reply
DY CONFIG OK”, and stop your car fuel pump or electricity as well.
6.8 Resume the Oil and Power System
Send SMS command TY+password+space+1 to the unit, It will reply TY
CONFIG OK” and resume your car fuel pump or electricity as well.
6.9 Set All Alarm Command
Note: All Alarms only will be sent to Center Number
Function
SMS Command
Remark
Set overspeed alarm
speed123456(space)080
SPEED,OK
Cancel overspeed alarm
speed123456(space)0
Set ignition on alarm
ACC123456(space)1
Cancel ignition on alarm
ACC123456(space)0
Default mode
Close all alarm
KC123456(space)0
Set SMS alarm
KC123456(space)1
Default mode
Set calling alarm
KC123456(space)2