V. TROUBLESHOOTING TIPS
The machine’s electrical power must be switched off and locked and tagged prior to any service repair
work.
The heat platen can cause burns. Check that the platen temperature reading on the display panel is below
25° C before handling.
PROBLEM POSSIBLE CAUSES SOLUTION
The platen does not heat up Faulty electronic board
Temperature probe not
working
Check and if necessary replace
Replace the temperature probe
The platen overheats The relay is stuck
The electronic board is
damaged
Replace the electronic board
Replace the electronic board
The timer does not count
down
The sensor is not being tripped
Check whether the sensor is tripped as the
descending heat platen moves past