EasyManua.ls Logo

Seiko CREDOR - Safety Device of Minute Repeater; Preventing Simultaneous Operation; Releasing the Safety Device

Seiko CREDOR
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Safety device of minute repeater mechanism
Failure of the minute repeater most frequently occurs due to operation of the crown when the
repeater mechanism operates.
In most watches which are mounted with a repeater function, when the crown is pulled out to
adjust the hand position while the minute repeater is chiming, an abnormal load is applied to
the gears or lever to cause a failure.
In order to prevent a failure from occurring because of the time setting while the minute repeater
is chiming, this watch is provided with a safety device that prevents both operations from being
performed at the same time.
The minute repeater cannot be activated while the time is
being adjusted.
When the crown is pulled out to the first click
position
Cannot be pushed in
The button located at the 8 o’clock
position cannot be pressed in the
state where the crown is pulled out to
the first click position.
* Please keep in mind that if the
button is forcibly pressed when the
crown is pulled out to the first click
position, this may result in a failure.
The following operations cannot be performed while the
minute repeater is chiming.
While chiming
Cannot be
pulled out
Slips
Setting the time
(The crown cannot be pulled out.)
Winding the mainsprings
(The mainsprings slip even if the
crown is turned.)
* The minute repeater mechanism
operates for a few seconds even
after chiming is finished. Please
make sure that operation of the
minute repeater mechanism is
finished by checking that the slow
governor is stopped.
* Please keep in mind that if the
crown is forcibly pulled out while
the minute repeater is chiming, this
may result in a failure.
14
HOW TO USE
How to use
When operation is not allowed (How to release the
safety device)
If the minute repeater is activated when the power reserve is in an “unwound” state (P. 9), the
following phenomena may occur.
The mainsprings cannot be wound
The crown cannot be pulled out
The minute repeater cannot be operated
As these phenomena are not due to a failure, please carry out the following operations to release
the safety device.
How to release the safety device
Flush head button
b
CAUTION
Use an object such as a wooden edge which is less likely to damage the case.
2
Wind the mainsprings to a“ fully wound” state.
“How to wind the mainspring”→ P. 8
* Although the watch may chime while the mainsprings are being wound, continue to wind
it as is.
3
Press the button located at the 8 o’clock position to activate the minute repeater.
“How to use the minute repeater”→ P. 12
4
Check the number of times the gongs are struck.
It is normal if the time indicated by the number of times the gongs are struck is the same
as the time indicated by the hands of the watch.
“Minute repeater function”→ P. 11
5
Reset the time.
“How to set the time”→ P. 10
1
Press the flush head button.
15
HOW TO USE
How to use
English

Related product manuals