Mounting the wall mounted push button control switch
Pry out the switch rocker place from the backplate and
fix the backplate to the wall near the exit of your garage
at a minimum height of 1.5 mtrs. using the two
No 6 x 30mm screws & wall plugs provided.
Mains Power Supply
1/ Your Seip door operator will require a 13A mains power point positioned
on the ceiling approx. 3.4mts back from the centre of the door frame.
(alternatively a 13A extension lead can be run from an existing point)
Limit-Switch Adjustment and Automatic Force Measurement
Please refer to the manufacturers installation manual enclosed
with your specific operator model for this procedure
Important Note
Unless the above procedure has been completed the unit will only run for a few seconds before stopping
Final Check
After completing the adjustment procedure, open and close the door making sure that the motor stops at least
30mm before the door reaches the door support track end buffers when open, and stops without applying excessive
pressure against the door frame when closed. (test the operation of the
manual release device because
if too much
force is applied against the door frame when the door is closed it will result in excessive force being require to
operate the
manual release device)
Testing The Safety Stop Sensitivity
Stand outside and start the door in the CLOSE direction, when half closed, restrain the door by hand and check that the motor
stops and reverses when hand pressure is applied to the lower edge of the door, a similar test should be carried out during the
OPEN phase to make sure the door stops when hand pressure is applied to the lower edge of the door
Attach the yellow safety warning label (supplied) in a prominent position on the back of the door
The Installation is now complete ! - Relax & enjoy many years of effortless luxury & convenience !
Security
The motor will automatically lock the door at the top when closed. If physical security is an important issue Amourelle's unique
Securi-Dor multi-point locking system can be fitted to enhance your security by automatically engaging additional side latches on
the door when closed.
Optional infra-red break-beam safety detector kit
This device can be fitted to your Seip garage door operator for added safety
These instructions have been compiled by Amourelle and should
be used in conjunction with the manufacturers installation instructions
For further technical advice phone: 01384 900 264
Amourelle Products, Unit 16 James Scott Rd, Halesowen,
West Midlands B63 2QT - www.Garage-Door-Automation.co.uk
The Garage Door Spares & Automation Specialists
Page 3 of 4
Wall control switch