0000138145 Pool Kronos 10 pH rev. 1.0
Pool Kronos 10 pH
General Features
Power Supply 220-240 Vac
Display 4 digits with 7 segments
Bnc connection for probe pH
Switch 3 position Priming, ON, Stand by
Peristaltic pump flowrate and pressure look at label on product
Measure Range pH: 3,8÷8,2 pH (resolution: 0.1 PH)
Dosage method ON-OFF ( Set Point adjustable)
Calibration method pH 1 Point
Switch position:
1) Priming position “the pump running” (Switch position MOM)
2) Normal position “the instrument measure pH and dosing”. (Switch position ON)
Keep pressed
key for 5 seconds to run calibration menu:
pH probe: the pump displays C7pH press
key and wait 60 seconds
Displays quality probe ex: C100
Press the button
to stop the calibration.
Keep pressed
key until flashing Setpoint value and press again to increase the value.
After 3 seconds from releasing the key
the value will be saved and the pump will display mem.
Value to set from 4 until 8 pH increase step by step 0.1 pH,
When the real measure is less than 3.8 pH and higher than 8.2 pH the measure displayed flashes.
3) Stand by position “The pump is stop” (Switch position OFF)
Keep Press
key for 3 seconds to run Setup menu:
pH setup menu:
1] Adjust dosage method for pH Acid or Alka
2] Temperature fixed Value 25°C

Related product manuals