Press and hold Enter and Esc keys for 5 seconds to access the setup programme.
Configure the device to dose acid products for negative pH adjustment.
Configure the device to dose alkaline products for positive pH adjustment.
Block or authorize the calibration function using the Enter key.
Block or authorize the Overdose Alarm (OFA) function using the Enter key.
Block or authorize the Flow function using the Enter key.
Block or authorize the Easy Cal function using the Enter key.
Confirm and exit the setup menu by pressing the Esc key.
Rinse the probe with H2O, then place it in the 7 pH buffer solution.
Press the Cal key for 5 seconds to initiate the 7 pH calibration.
Please wait during calibration for 1 minute after the initial 7 pH step.
Rinse probe with H2O, then place it into the 4 pH buffer solution.
Press Enter key to calibrate the second point (4 pH buffer solution).
Press Enter key to save the calibration settings and exit the process.
Details on First and Second OFA alarms, their triggers, and resolution steps.
Indicates presence of incoming flow, enslaved by the filter pump.
Table of alarms, LEDs, relays, and required actions for system errors.
Steps to restore default settings by powering off, pressing keys, and powering on.