Use with salt chlorinator:
To prevent the risk of system malfunctioning or damage, observe the following instructions:
1/ Position the pH measuring probe prior to the chlorinator cell.
2/
To eliminate eddy currents, connect the pool water to an electrical ground point
3/ Position the product injection point after the chlorinator cell.
Positioning the probe:
For optimum probe reading, position it perpendicular to the tubing (probe cable extracted upward).
!
The probe’s angle of inclination must never exceed 45° from vertical.
Electrical wiring:
Connect the power supply cable to the mains and the servocontrol pre-wired cable to the auxiliary
contact of the filter box (230 Vca)
Set Point adjustment
Keep the key pressed down and set the desired value using the
and keys.
Adjustment (Setup)
Press the and keys
(simultaneously) for 5 seconds to
enter the SETUP programme
enables you to dose an acid
product (negative pH)
Alka enables you to dose an
alkaline product (positive pH). Set
using the key
Press the key twice to progress
to the Cal light
Block or authorise calibration using
the key
Press the key to progress to the
OFA light
(see page 4)
Block or authorise the OFA alarm
using the key
Press the key to progress to the
Flow light (
see page
4)
Block or authorise the Flow function
using the key
Press the key to progress to the
Easy Cal light
Block or authorise the Easy Cal
function using the key
Confirm and exit the setup menu
using the key
-{}-