PoolDose | pH · ORP · Chlorine
0000138994 rev. 1.1 EN
6
§ Calibration CL: 2 points, Disable,
§ Calibration Temp: Reference, Disable,
§ Dosing Type pH: Proportional, OFF, Timed, On/OFF
§ Dosing Type ORP: Proportional, OFF, Timed, On/OFF
o Note: The ORP dosing is disabled if Dosing type chlorine is different than
OFF
§ Dosing Type Chlorine: Proportional, OFF, Timed, On/OFF
§ Aux Relay
• Aux1 Relay: pH, Disable
• Aux2 Relay: Chlorine, ORP, Disable
o Note: Aux1 and Aux2 relays dose with ON/OFF method
§ Password: 0000 (Note: password disabled, set a value other than: 0000)
§ Reset Calibration: (Note: select the measure to reset: pH; Chlorine; ORP)
§ Reset All Parameters
§ PROG Control Panel: displays the electrical signals
§ Reed (display error, when red): NO/NC
§ Power ON Delay: Disables the dosing pumps for the set time
§ Flow Delay: Disables the dosing pumps for the set time
Note: Timeout setting menu, after 120 seconds without action the controller escape itself without saving parameters.
View Parameters
Calibration Menu:
Press (3 seconds) and calibrate probe pH, Chlorine, Temperature, ORP
1.4ppm 7.4pH
25°C 720mV
ORP
Measure
Alarms:
Lev CL(ORP)
OFA ORP
pH
measure
Alarms:
Lel pH
OFA CL
Free Chlorine Measure
Alarms
Lev CL
OFA CL
Temperature or Totalizer
Flowrate measure,
Moreover:
Alarms sharing messages
• Circ. Pump OFF
• Flow (Reed OFF)
• WiFi OFF
• Remote standby
deletes all measures