TEC Series v 3.2X
Page 18
PRINTER REPORTS AND MESSAGES continued
CONNECTING A PERSONAL COMPUTER TO THE SERIAL PORT
The TEC may be remotely programmed by personal
computers that already have a terminal communications
program. Set the communications parameters to the
TEC default, 9600 baud, 8 bits, 1 stop bit, No parity,
(8,N,1) going from the COMM port on your computer to
the serial board on the TEC. Check the TEC from the
keypad on the front of the TEC to make sure that the TEC
communications parameters are also set to 9600 baud. If
your software supports terminal emulation, set it to VT-
100B emulation. If it does not, program the TEC terminal
type from VT-100B to "dumb" terminal mode. See Pg. 36.
To start communications press the "Esc" (escape) key on
your computer. Do not press any other keys until the
PASSWORD prompt appears on the CRT screen of your
personal computer:
PASSWORD
You have 10 seconds to begin entering the password. If you wait more than 10 seconds
before entering the password the TEC will revert back to normal operation and you will have to re-
enter the "Esc" key again. All TEC systems leave SES with a factory password of 777777. As the
password is entered, the screen will replace each character with an “*” to keep the password
confidential. After the password is entered, the main menu will be displayed. If more than 60
seconds elapse without a keystroke, the TEC will disconnect. It will then be necessary to press
"Esc" (escape) and start again.
Some examples of typical logging report messages are shown below.
PROGRAMMING MODE ENTERED ON KEYPAD 00:00/00/00
EXIT PROGRAMMING MODE 00:00 00/00/00
ENT 1 LATCHED OPEN BY CLOCK 00:00 00/00/00
ENT 2 LATCHED OPEN BY CLOCK 00:00 00/00/00
CARD 00790 CODE 003 MORRIS, NORMAN ENTRANCE 1 OPEN 00:00 00/00/00
CARD 01291 CODE 002 DAVIS, JIM LEVEL NOT SET READER 2 00:00 00/00/00
CODE 004 SHEPARD, JULIUS DIALED 00:00 00/00/00
CODE 004 SHEPARD, JULIUS ENTRANCE 2 OPEN 00:00 00/00/00
ENT 2 LOCKED 00:00 00/00/00
CARD 00257 CODE 003 DOE, JOHN DAY NOT VALID READER 2 00:00 00/00/00
CARD 00260 CODE 002 CHAVEZ, CAESAR OUTSIDE TIMEZONE READER 2 00:00 00/00/00
CARD 00764 CODE 004 SHEPARD, JULIUS INVALID ENTRANCE 1 00:00 00/00/00
PIN 0001 CODE 001 BROWN, BOB OUTSIDE TIMEZONE ENTRANCE 1 00:00 00/00/00
ENT 1 LOCKED 00:00 00/00/00
CODE 000 PASTOR, JOHN DIALED 00:00 00/00/00
CALLER HUNGUP 00:00 00/00/00
TAMPER 1 CLOSED 00:00 00/00/00
TAMPER 1 OPEN 00:00 00/00/00
PIN 0003 CODE 003 DOE, JOHN DAY NOT VALID ENTRANCE 1 00:00 00/00/00
INVALID CODE 911 ATTEMPTED 00:00 00/00/00
PIN 911 WALLACE, WILL ENTRANCE 1 OPEN 00:00 00/00/00
ENT 1 LOCKED 00:00 00/00/00
INVALID PASSWORD ATTEMPTED KEYPAD 00:00 00/00/00