TEC Series v 3.2X
Page 44
SYSTEM PARAMETERS
ACCESS LEVELS continued
Use the table below to help keep track of which Access Levels are required for this installation.
Writing them down in the table provided will help reduce programming entry errors.
AUTOMATIC UNLOCK AND RELOCK BY TIME ZONE
The example on the next page shows how a business might keep two entrances open during
peak employee traffic, and secure those two entrances at all other times. Time Zone 1 is valid for one
half hour in the morning, Monday through Friday. Time Zone 2 is valid for one half hour in the
afternoon, Monday through Friday. Time Zone 0 is valid all the time, except Holidays.
Each Time Zone is assigned to a different Access Level. Both entrances are selected in the
Access Levels. The morning and the afternoon Access Levels are grouped together in Access Group
1.
By setting Entrance Group 1 to Access Group 1, the entrance will automatically unlock during
peak traffic, and relock at all other times. Employees whose PIN codes or cards are set to Access
Level 0, can open the entrance at all other times. If employees try to use their PIN code or Card while
the entrances are unlocked, the display on the TEC will show "OPEN".
ENTRANCE
ACCESS TIME
0
1
2
3
4
5
6
7
SETUP AND PROGRAMMING